DM-6 Independent Wall Lining - Acoustic Standard

Introduction

Suited for lining reinforced concrete walls and steel framed walls, walls which have severe irregular surfaces and external walls that have suffered moisture ingress,  but then treated with appropriate moisture proofing systems. Range of cavity > 70mm.

Suitable to be applied at:

  • Studio Music
  • Ballroom/Hall
  • Any other area that requires acoustical performance

Supporting Material:

  • Frame: JayaBMS Wall Track, JayaBMS C Stud, JayaBMS Direct Fixed Clip + JayaBMS Furring
  • Lining: 1 layer of Jayaboard Sheetrock 12mm (1 sisi) + 1 layer of Jayabell 12mm
  • Jointing: JayaCompound as Jayaboard Recommendation.

Use Hitung Material fiture to help you figure total materials needed.

Specifications:

  • Fire Rating: +/- X + 15
  • Acoustic Rating: STC 48 (no insulation), STC 60 (insulation 60kg/m3)
  • Grade (BS 5234): Medium Duty

Notes:

  • All the materials above calculated based on a room with a size of (3x33.33m). Another room sizes should be considered further
  • Vertical frame gap (Furring) max. of 600mm.
  • All the materials above needs to be reconfirmed by the Contractor / Applicators regarding bookings material inquiry order.
  • Exclude waste material