SS22 Fire Rating 3 Hours

Introduction

This partition system developed to meet the requirements of Fire Resistant up to 3 hours (FRL -180/180).

Suitable to be applied at:

  • Hotel partition
  • Factory
  • Warehouse
  • Any other area that require Fire Rating Performance up to 3 hours.

Supporting Material:

  • Frame: JayaBMS Wall Track, JayaBMS C Stud, JayaBMS Deflection Head Track, JayaBMS Direct fixed clip + JayaBMS Furring Channel (Thickness min. 0,5mm BMT)
  • Lining: 2 layer of Firestop 16mm (2 sides) + 1 layer of  Jayabell 12mm (1 side)
  • Jointing: JayaCompound as Jayaboard recommendation.

Use Hitung Material fiture to help you figure total materials needed.

Specifications:

  • Fire Rating: Up to FRL -/180/180
  • Acoustic Rating: STC 57 (no insulation), STC 63 (insulation 60kg/m3)
  • Weight: 80 Kg/m2
  • Grade (BS 5234): Severe Duty

Notes:

  • All the materials above calculated based on a room with a size of (3 x 33.33m).  Another room sizes should be considered further.
  • Stud frame gap max. of 600mm.
  • All the materials above needs to be reconfirmed by the Contractor/ Applicators regarding bookings material inquiry order.
  • Exclude waste material.