CS15 Fire Rating Ceiling 1 Hour

Introduction

This ceiling system developed to meet the requirements of Fire Resistant up to  1 jam (FRL-60/60).

Suitable to applied at:

  • Laboratory.
  • Ceiling for Generator room.
  • Any other area that require Fire Resistance performance.

Supporting Material:

  • Frame: JayaBMS Hanger System (Bracket PN 220/221, Clip Adjuster PN 224, Rod PN 226), JayaBMS Top Cross Rail PN 202, JayaBMS Furring PN-205
  • Board: 2 Layer of Firestop 16mm
  • Jointing: JayaCompound as Jayaboard Recommendation.

Use Hitung Material fiture to help you figure total materials needed.

Specifications:

  • Fire Rating: (FRL -/60/60).
  • Weight: 28.2 Kg/m2

Notes:

  • All the materials above calculated based on a room with a size of (10x10m). Another room sizes should be considered further.
  • Suspension gap max. of 900mm
  • Primary frames gap max. of 900mm
  • Secondary frames gap max. of 400mm
  • All the materials above needs to be reconfirmed by the Contractor / Applicators regarding bookings material inquiry order.
  • Exclude waste material.